decisions/quantities.md on GitHub, at the commit these pages were built from
Quantities on lab results
Status: ruled, 2026-10-22, from the research on #131 and the owner's rulings of that day; applied by #131, which writes
the terms, shapes, queries and feature rules. It adds typed terms beside health:resultValue, health:resultUnit and
health:referenceRange, which stay, and replaces the value rule of same-result.rq (removed 2026-11-18) in a new rule list version. Names,
nested nodes and a version's hash are naming.md and currency.md; a value absent for a reason is
partial-dates-and-absent-reasons.md's (#133). Terms are local names in the one unversioned Cascade namespace (#193).
Question
A lab result's value, unit and reference range are strings (ontologies/health/v1/health.ttl:151-167), so nothing can
compare, sort or check them. The matcher joins two results only when their value strings are identical and ignores
units (same-result.rq:12-13, removed 2026-11-18), so 6.80 and 6.8 differ and 95 mg/dL equals 95 mmol/L. The FHIR adapter glues a
comparator to the number ("<5.7"). A pod has no server to ask what a number meant: the typed form must hash alike on
every runtime, since a version is named by its content, and must say no more than the source did.
What others do
Each quotation was read at its source on 2026-10-22 (verified) unless marked.
- FHIR R4
decimalis the "union of xs:decimal and xs:double", its regex allows[eE]exponents, and "0.010 is regarded as different to 0.01, and the original precision should be preserved".Quantity: "If no comparator is specified, the value is a point value (i.e. '='). The comparator element can never be ignored"; R4 has four codes,<<=>=>; R5 addsad, "Sufficient to achieve this total quantity"; the R6 build adds~, "approximately equal … A recommended value for the approximation is 10%". "it cannot be assumed that the unit actually contains a valid UCUM unit"; US Core 9: "The system SHALL be UCUM for coded quantity units".SimpleQuantitysqty-1: "The comparator is not used on a SimpleQuantity".Range: "The low and the high values are inclusive", and a missing bound means "not known".referenceRangeis 0..*, "interpreted as an 'OR'", and onlow: "If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3)".Ratiois for "titers (e.g. 1:128)";dataAbsentReason"SHALL only be present if Observation.value[x] is not present". FHIR RDF, R5 and the build: "any value with an 'e' or 'E' in it is an xsd:double, otherwise it is an xsd:decimal"; the R4 RDF page states no rule. - CDA and C-CDA.
PQ.valueis aREAL, "the number of significant decimal digits is known as the precision"; the XML ITS makesreala union ofxsd:decimalandxsd:double.IVXB_PQ.inclusivedefaults totrue; a range isIVL_PQ, a ratioRTO, an absent value anullFlavor(withunit="1"), includingTRC, "greater than zero, but too small to be quantified". C-CDA 5.0.0 makesPQ/@unit1..1 and "SHOULD be taken from UnitsOfMeasureCaseSensitive (preferred)". C-CDA on FHIR maps a one-boundIVL_PQresult to a Quantity with"comparator": "<="(<wheninclusive="false"), and of several reference ranges "only map the one with interpretationCode = 'N'". - openEHR
DV_QUANTITYhasmagnitude: Real, a separateprecisionin decimal places ("-1 implies no limit"), anaccuracy, andmagnitude_status,=<><=>=~, "If not present, assumed meaning is '='", with no tolerance for~.normal_rangeis oneDV_INTERVALwithlower_includedandupper_included, plusother_reference_ranges, each with ameaning. Units are UCUM "(case-sensitive form) by default". - HL7 v2.5.1
NM: "'01.20' and '1.2,' are identical"; no exponent.SN.1is><>=<==<>, "If this component is not valued, it defaults to equal".OBX-6defaults to ISO+, and "All unit abbreviations are case insensitive".OBX-7is one string, "> lower limit (if no upper limit, e.g., >10)". - SPHN types a value
xsd:double, has four comparator individuals, oneReferenceRange(0..1), and aUnitwhose code is a UCUM class IRI such asucum:cblbeatscbrpermin. OMOP keepsvalue_as_numberas a float, anoperator_concept_idof<<==>=>with "NULL if there's an exact numeric value", onerange_lowandrange_high, and the verbatimvalue_source_valueandunit_source_value. - UCUM 2.2 defines codes as strings and no IRIs. §6: "any fully conformant parser must discard all annotations";
§12:
%{vol},kg{total}and{RBC}"are equivalent to '%', 'kg'" and "1". Its case-insensitive variant is "incompatible" with the case-sensitive one. Its licence 1.1 grants use "for the purposes of developing and commercializing Software Applications" and says "You may not … use the Work to create Derivative Works". - QUDT v3.5.3 (CC-BY-4.0 by the GitHub API) gives 2,438 of 2,940 units a
ucumCode, all dotted (mg.dL-1);10*3.uL-1,U.L-1andk[IU].L-1are absent (verified, counted from its units file). - XSD 1.1
decimal: "Precision is not reflected in this value space; the number 2.0 is not distinct from the number 2.00"; its lexical space has no exponent. SPARQL 1.1:=on numerics isop:numeric-equal,sameTermis "the same RDF term", and a basic graph pattern joins on the term, so"6.80"and"6.8"join only through a filter. - Oxigraph 0.5.11, which
cascade-bridge-rspins, stores a parsablexsd:decimalby value and prints it in canonical form; its own test turns"1.0"into"1"(verified in its code; that a Bridge run emits"6.8"for"6.80"is inferred, not observed). The FHIR adapter keeps"6.80"today only because it writes anxsd:string(cascade-bridge-adapter-fhir-r4/fixtures/expected/lab-every-mapped-element.ttl:20, verified). - Matching. No standard defines a same result. Particle: "Every non UUID field has to have an identical value"; de Graauw matches "the same code and value on the same datetime", units unmentioned.
Sources: FHIR R4 datatypes (https://hl7.org/fhir/R4/datatypes.html), SimpleQuantity
(https://hl7.org/fhir/R4/simplequantity.profile.json.html), Observation (https://hl7.org/fhir/R4/observation-definitions.html),
comparator value sets (https://hl7.org/fhir/R4/valueset-quantity-comparator.html,
https://hl7.org/fhir/R5/valueset-quantity-comparator.html, https://build.fhir.org/valueset-quantity-comparator.html),
reference-range meanings (https://hl7.org/fhir/R4/valueset-referencerange-meaning.html), FHIR RDF
(https://hl7.org/fhir/R4/rdf.html, https://hl7.org/fhir/R5/rdf.html, https://build.fhir.org/rdf.html), the R4 Turtle
example (https://hl7.org/fhir/R4/observation-example.ttl.html), US Core 9.0.0 lab
(https://hl7.org/fhir/us/core/StructureDefinition-us-core-observation-lab.html); CDA PQ
(https://hl7.org/cda/stds/core/StructureDefinition-PQ-definitions.html) and its IVXB-PQ, RTO-PQ-PQ and REAL pages, CDA
null flavours (https://hl7.org/cda/stds/core/ValueSet-CDANullFlavor.html), the v3 XML ITS from the OASIS mirror
(https://www.oasis-open.org/committees/ubl/lcsc/doc/qateam/Comment%20work%20from%20HL7/datatypes-its-xml.html), C-CDA
5.0.0 Result Observation (https://hl7.org/cda/us/ccda/StructureDefinition-ResultObservation-definitions.html), C-CDA on
FHIR 2.0.0 (https://hl7.org/fhir/us/ccda/en/CF-results.html, https://hl7.org/fhir/us/ccda/en/mappingGuidance.html);
openEHR (https://specifications.openehr.org/releases/RM/latest/data_types.html,
https://specifications.openehr.org/releases/BASE/latest/foundation_types.html,
https://specifications.openehr.org/releases/RM/latest/data_structures.html); HL7 v2.5.1
(https://www.hl7.eu/HL7v2x/v251/std251/ch02a.html, https://www.hl7.eu/HL7v2x/v251/std251/ch07.html) and the v2-to-FHIR SN
map (https://hl7.org/fhir/uv/v2mappings/ConceptMap-datatype-sn-to-quantity.html); SPHN
(https://www.biomedit.ch/rdf/sphn-schema/sphn,
https://sphn-semantic-framework.readthedocs.io/en/latest/user_guide/data_generation.html); OMOP CDM 5.4
(https://ohdsi.github.io/CommonDataModel/cdm54.html); UCUM 2.2 (https://ucum.org/ucum), its licence
(https://ucum.org/license); QUDT (https://github.com/qudt/qudt-public-repo/blob/v3.5.3/src/main/rdf/vocab/unit/VOCAB_QUDT-UNITS-ALL.ttl);
w3id.org/uom (https://github.com/units-of-measurement/units-of-measurement); Vreeman et al. 2018 on LOINC's example
units (https://pmc.ncbi.nlm.nih.gov/articles/PMC6251552); XSD 1.1 (https://www.w3.org/TR/xmlschema11-2/); SPARQL 1.1
(https://www.w3.org/TR/sparql11-query/); ucum-lhc (https://github.com/lhncbc/ucum-lhc); Oxigraph v0.5.11's
numeric_encoder.rs and decimal.rs; Particle (https://docs.particlehealth.com/docs/data-deduplication), Health
Gorilla (https://apidocs.healthgorilla.com/getting-started/platform-overview/data-lifecycle), de Graauw
(https://www.marcdegraauw.com/2024/01/09/deduplicating-patient-summaries/), Marley #1258
(https://github.com/earthians/marley/pull/1258). The research on #131
(https://github.com/the-cascade-protocol/cascade-vocabulary/issues/131#issuecomment-6345803866); the quantity pattern
(https://github.com/the-cascade-protocol/cascade-runtime-js/issues/183#issuecomment-6093896826) and its review against FHIR,
openEHR, UCUM, SPHN and OMOP (https://github.com/the-cascade-protocol/cascade-runtime-js/issues/183#issuecomment-6135136922).
Choice
Every row is ruled, 2026-10-22. Where the research corrected a premise of #131, the row says so.
| thing | prior art | what we do | borrowed or diverged | Rules that cite it |
|---|---|---|---|---|
| quantity node | FHIR Quantity; openEHR DV_QUANTITY; naming.md's #source-version |
a Quantity nested in the version as <version>#value, #reference-low, #reference-high, hashed with it, carrying decimalValue, writtenValue, quantityComparator, ucumUnit, unitText; reached by resultQuantity, referenceRangeLow, referenceRangeHigh (and a ratio's resultRatioNumerator and resultRatioDenominator, a range's resultRangeLow and resultRangeHigh); resultValue and referenceRange stay as text, and resultUnit is no longer written for a quantity, whose unit is on its node and which the lab-results view shows from there, but is written beside a value an adapter refused to type and kept as text (ontologies/cascade.shapes.ttl) |
borrowed from FHIR's parts; the nesting is naming.md's |
No rule cites this row. |
| number | FHIR keeps the written form; v2 and XSD say it carries nothing; SPHN, OMOP a float | two literals on the quantity node, both hashed into the version: decimalValue, an xsd:decimal by value, which the store canonicalises ("6.80" to "6.8"), for comparison, sorting and bounds; writtenValue, a plain string of the exact characters the source sent ("6.80"), which no store normalises; openEHR's precision is derivable by counting places and is not stored; an exponent (1.2e3) is a plain decimal in the typed literal and kept as sent in the string; the written form no longer rides on health:resultValue (ontologies/cascade.shapes.ttl) |
borrowed from FHIR for precision, kept in the written form, and from XSD for the value; diverges from SPHN's and OMOP's float; corrects #131's "exact xsd:decimal as the source wrote it", which the Bridge's store cannot keep |
No rule cites this row. |
| comparator | FHIR R4 and SPHN four; openEHR adds = ~; v2 adds = <>; R5 ad |
sh:in ("<" "<=" ">=" ">"); = written as none; ~, <> and ad refused with a finding, the text kept; a comparator makes the value a bound (ontologies/cascade.shapes.ttl) |
borrowed from FHIR R4; diverges from openEHR's ~ |
No rule cites this row. |
| reference range | FHIR 0..*; C-CDA on FHIR the N one; openEHR one normal plus others; v2, SPHN, OMOP one |
bounds inclusive, never a comparator on one (sqty-1); a missing bound one-sided; one typed range, the one the source marks normal or the only one, the rest as text; a one-bound IVL_PQ result from C-CDA becomes a quantity with a comparator, as C-CDA on FHIR maps it, never a Range result, since a bound with nothing on the other side is what a comparator says (ontologies/cascade.shapes.ttl) |
borrowed from FHIR's referenceRange and C-CDA on FHIR; corrects #131's "a missing bound means unknown", which is Range's wording, and the #183 table's keeping a one-bound result as a range |
No rule cites this row. |
| unit | FHIR code when system is UCUM; C-CDA "SHOULD" UCUM; v2 ISO+, case-insensitive; UCUM §6 |
ucumUnit is the source's exact string, case and {annotations} kept, only where the source says it is case-sensitive UCUM (FHIR system, C-CDA @unit under a Warning shape); unitText is the display unit; a unit outside UCUM, and every v2 OBX-6, is unitText alone. The alternatives: store the annotation-stripped form instead, or both (ontologies/cascade.shapes.ttl) |
borrowed from FHIR; corrects #183's "a non-UCUM C-CDA unit is a source error" | No rule cites this row. |
| unit IRI | UCUM none; SPHN UCUM classes; QUDT ucumCode, dotted |
none; a QUDT or SPHN IRI, if ever, is a table beside the string (ontologies/cascade.shapes.ttl) |
borrowed from UCUM; corrects #131's "no IRIs for units": UCUM defines none, others do | No rule cites this row. |
| value kinds | FHIR value[x]; CDA PQ, RTO, IVL_PQ, CD, ST; openEHR DV_QUANTITY, DV_PROPORTION, DV_INTERVAL, DV_CODED_TEXT, DV_TEXT |
five, the set the three agree on, and one property naming which a result's value is: Quantity (row "number"); Ratio, a numerator and a denominator each a quantity node, a titre 1:64 a ratio with no unit; Range, a low and a high bound, the node shape the reference range row defines, reused; Coded, the answer as a code IRI, as every coded thing here is; Text, what is left, named as text and never matched by value. A value absent for a reason is no kind: it is row 7 of partial-dates-and-absent-reasons.md (ontologies/cascade.shapes.ttl) |
borrowed from FHIR, CDA and openEHR | No rule cites this row. |
| matcher | no standard defines a duplicate; HL7 v2 filler order number and observation id; FHIR identifier; C-CDA entry id; Particle every field; de Graauw code, value, datetime |
four tiers, a new rule list version: (i) a shared business identifier within one organisation joins for certain, first; (ii) same code, same instant, equal value, same unit is a strong join; (iii) same code and instant with a different value, or a value of another kind, is never Same and is a finding for review, coded answers only when of one code system; (iv) same code and instant with units that are not one UCUM unit is a finding for review, not joined, until conversion is in scope; units are one UCUM unit when equal once annotations are dropped and the litre's l and L are read as one, with any prefix, every other case kept; a different instant never joins, a time with no zone is compared only with another with none, as written, and a day-only time drops to likely, surfaced. Replaces M12's (removed 2026-11-18) value clause; the four cases become examples in runtime/matcher.feature: rule M21 applies tiers (ii), (iii) as R16's finding for review and (iv) as R17's, the day-only drop as R15; rule M22 applies tier (i) as R18, a shared dct:identifier of a named system, a shared code and one time, from documents naming one organisation or two judged one (#270) |
ours: no standard defines a duplicate; the identifiers are the standards' | |
| conversion | ucum-lhc within a dimension; LOINC molar masses | out of scope; a unit that differs goes to review (the matcher's tier iv) (runtime/matcher.feature, M21) |
waits on UCUM's licence |
Why
Two literals, one job each. (rows "quantity node", "number") A version is named by a hash of its triples (currency.md), so two runtimes must
write one lexical form for one state. XSD defines one canonical decimal and Oxigraph prints it whatever it was given
(verified in its code), so decimalValue is alike on every runtime, and writtenValue is a string no store rewrites,
so the hash over both is deterministic. The decimal compares, sorts and bounds, XSD's rule; the string keeps the
precision FHIR says "should be preserved", and openEHR's decimal places are counted from it. FHIR says 0.010 and
0.01 differ, v2 and XSD that they do not; with a literal for each answer the pod need not take a side.
health:resultValue no longer carries the written form: it is off the node and glues on a comparator ("<5.7").
A decimal, not a float. (row "number") FHIR decimal and v3 REAL admit an exact decimal, and a double turns 0.1 into another
number. An exponent is exact as a plain decimal, so 1.2e3 as 1200 loses only the spelling, which writtenValue
keeps.
Four comparators, because four is what every source agrees on. (row "comparator") The four are the intersection of FHIR R4, openEHR,
v2, SPHN and OMOP. = means the same as none in all three that have it. ~ is openEHR's and an R6 CI build's, with no
tolerance in one and 10% recommended in the other; a value that is "about" something can neither be compared as a
point nor as a bound. ad is about dosing and <> is v2's alone. A comparator makes the value a bound, which FHIR
says "can never be ignored", so a query testing the number still knows it is a bound.
One range, and a missing bound is one-sided. (row "reference range") FHIR's referenceRange.low says an omitted bound is "meaningless
(e.g. reference range is <=2.3)": a range with a high only is everything below it, which is how a lab writes <5.7.
Range's "not known" is the generic type's, not the reference range's. One typed range is what v2, SPHN and OMOP hold
and what C-CDA on FHIR keeps; FHIR says "most observations only have one generic reference range", and the rest stay in
health:referenceRange, so nothing is dropped. A bound carries no comparator because FHIR forbids one and the
inclusivity is the range's.
The unit as the source wrote it, compared as UCUM says. (row "unit") UCUM is case-sensitive and its case-insensitive variant is
"incompatible", so a v2 unit, case-insensitive by default, is display text and never ucumUnit. Storing the exact
string keeps what the source said; UCUM §6 says annotations carry nothing and a conformant parser discards them, so the
matcher strips them rather than the store, and {beats}/min equals /min while both strings survive. UCUM also
defines the litre twice, l and L, L being "1 l", both metric so prefixable (§31, Table 5), and says "In the case
sensitive variant the liter is defined both with an upper case 'L' and a lower case 'l'" (https://ucum.org/ucum, read
2026-10-24): mmol/l and mmol/L are one unit by UCUM's own definitions, so the matcher reads the two symbols as one.
That is not conversion: no factor is applied, and every other case difference is kept, since UCUM is case-sensitive
and Mmol/L is another unit.
No unit IRIs yet. (row "unit IRI") UCUM defines none. QUDT's codes are dotted, so mg.dL-1 never string-matches the mg/dL labs
send, and 10*3/uL and U/L, among the commonest lab units, are absent (verified, counted). SPHN's classes exist, but
under what permission it republishes UCUM was not found (unverified). An IRI needs a normaliser and a gap table, and a
string needs neither.
Five kinds, because three standards agree on five. (row "value kinds") FHIR's value[x], CDA's datatypes and openEHR's DV_ types
each type a quantity, a ratio, a range, a code and text, so the set is borrowed whole. Deferring four of them left the
matcher half a rule: a titre or a "positive" could never dedupe. The cost is two small node shapes mirroring the
quantity, one kind property, and a matcher rule per kind. The adapter knows a ratio from a quantity because FHIR sends
a Ratio and CDA an RTO, never by reading 1:64 as text. A range result reuses the reference range row's bounds,
so one shape checks both; a coded answer is an IRI, as every coded thing here is; text is what is left, and two
spellings of one finding are not one value. An absent value is a reason, not a kind: row 7 of
partial-dates-and-absent-reasons.md.
What a same result needs, tiered. (row "matcher") No standard defines a duplicate, so the rule is ours, its strongest input is
the standards' identifiers, and the rubric's fourth test orders it by how sure each tier is. (i) Within one
organisation a shared business identifier is certain: HL7 v2's filler order number with the observation id, "a
permanent identifier for an order and its associated observations" (quoted in the ruling; not re-read here), FHIR's
identifier, C-CDA's entry id; it is republishing-sources.md's within-organisation rule, run first. R18 compares
the identifier as the literal #212 made an organisation's, its value typed by its system, which a C-CDA id reaches
through HL7's CDA-to-FHIR identifier mapping, so one result in a hospital's FHIR and C-CDA summaries carries one
identifier; one with no system is never compared, since nothing says which of an organisation's systems issued it. It
also asks for one code, as naming.md says a judgment does ("share one plus a code"): a source copying an organizer's
accession onto each member would otherwise join a whole panel. And it asks for one clinically relevant time, compared
as tier (ii) compares instants, or one of the two stating none: a source that files serial draws under one accession
would otherwise join every draw of a day, or of a year, into one; a correction keeps its specimen's time, so it still
joins. It does not compare the value, so a correction's second value is not tier (iii)'s finding to be resolved by
hand: the review page leaves a finding of two results R18 joins out when one of the two says it was corrected or
amended (workflowStatus), and lists it otherwise, since two channels of one organisation disagreeing on a value
neither marks as a correction is what a person should see. The organisation is an organisation record a record's
documents name as custodian or author; an agent with no record, as Apple Health's export names its author, is no
organisation, and a pull names none, so R18 joins no pulled record, holding them apart while which organisation a
record from a shared server belongs to is open in republishing-sources.md. Two organisation records are one only by
a person's judgment of organisations (cascade:currentlySameOrganization), never because a join of two servers made
two organisations pulled from them one record, for the same reason.
The identifier term. (row "matcher") dct:identifier, "an unambiguous reference to the resource within a given context", with
range rdfs:Literal and no domain, so a literal typed by its system is one, as #212 writes an organisation's
org:identifier. Of a version of a lab result it is a business identifier its source gave the result: a FHIR
Observation.identifier's value typed by its system, a C-CDA observation's id as HL7's CDA-to-FHIR identifier
mapping makes it one, a UUID in lower case in both; one with no system is a plain string. Looked at
and failed: org:identifier, whose domain org:Organization would make a lab result an organisation; skos:notation,
a concept's notation within its scheme, not a record's identifier; FHIR RDF's fhir:identifier and ADMS's
adms:identifier, each a node with a system and a value, where #212 settled one literal; schema:identifier, whose
range is a PropertyValue, text or a URL; SPHN's hasSharedIdentifier, a sameness asserted across providers, not an
identifier a source gave. (ii) Same
code, instant, value and unit is strong. Values are equal by kind: quantities by decimalValue through FILTER(?a = ?b), never a shared variable, which joins "6.8" and "6.80" only on a store that canonicalises (inferred), with
the same comparator or none on both; ratios by both parts; ranges by both bounds; coded by the same IRI; text never.
Units are equal after UCUM's annotations are stripped (§6), the litre's two symbols read as one (§31), other case
kept. A time with no zone, as a C-CDA TS may be written, names no moment, so it is compared only with another written
with none, as written; one with a zone and one without never compare. (iii) A different value at the same code and
instant is never Same: a correction should have arrived as a new version, and here it did not, so a person sees it.
Values of two kinds are different values too. Coded answers of two code systems are not, since a rule cannot tell them
from one answer coded twice.
(iv) Units that are not one UCUM unit may not differ in dimension, mmol/L against mg/dL, so the pair goes to review
unjoined until conversion is in scope, as a finding the matcher files, so the review page reads it rather than
comparing every pair of results on each read (0.20 s against 1.30 s for the review question over 3,000 results). A different instant never joins; a result stamped only to the day is compared by day
and drops to likely, surfaced, since two draws in a day are common for inpatients. A changed rule is a new rule list
version, as naming.md requires, so the old rule's matcher judgments stop counting by derivation.
Conversion waits. (row "conversion") Within a dimension it is mechanical, but mass to molar needs a molar mass per LOINC code, and UCUM's licence forbids derivative works; whether a published LOINC-keyed table is one is a legal question (unverified).
Alternatives that lost
- A float or double, as SPHN and OMOP do. The strongest case: two of the standards the vocabulary cites, and every engine compares doubles. A double is not the number a lab reported, and FHIR and v3 admit an exact decimal.
- The value alone, the written form on
health:resultValue. The strongest case: one literal, and the text held"6.80". That text is off the node with a comparator glued on, so a page reading precision would parse it. - A precision attribute, as openEHR has. The strongest case: twenty years of practice, and it survives any store.
The places are counted from
writtenValue, and a second field to keep in step is a second place to disagree. - A string, as today. The strongest case: lossless. Nothing can compare or check it, and
"<5.7"hides a bound. - Many typed ranges, as FHIR allows. The strongest case: lossless, and FHIR's model. A range per age, sex and phase
needs a typed
appliesTothe pod has no use for yet; the text keeps them, and aReferenceRangenode can come later. - Unit IRIs as the unit. The strongest case: an IRI is what RDF joins on, and SPHN does it. UCUM defines none, the best-kept set is dotted and lacks common lab units, and the table would be ours to maintain.
~as a fifth comparator. The strongest case: openEHR has it and FHIR R6 may. No R4 source can send it, its tolerance is undefined or 10% by recommendation, and the matcher could compare it with nothing.- Units compared as exact strings, as #131 says. The strongest case: simplest, and never wrong when it says equal.
UCUM says a conformant parser discards annotations, so equal units with and without
{beats}would go to review. - Refusing to canonicalise. The strongest case: FHIR's "the original precision should be preserved". Oxigraph, which the Bridge pins, stores by value, so the form a Bridge writes is not the adapter's to choose (inferred).
- Text only, named as such, for every value but a quantity. The strongest case: nothing new to build for alpha. A titre or a "positive" could then never dedupe, and all three standards already type them.
- One rule for a same result. The strongest case: it is today's rule plus units. It treats a certain join and a weak one alike, and is silent on one code and instant with two values, the case a person most needs to see.
Still open
Each with its lean, and the one fact that decides it:
- Order of landing. Settled as fallout: #193 landed first, so #131 renames every lab version by its new content.
- Stripping annotations. Whether a SPARQL
REPLACEstrips as UCUM's grammar does, a lone annotation being1. - Conversion. Out of scope. A reading of UCUM's licence on a LOINC-keyed table.
What would change our mind
A store every runtime uses keeping a decimal's lexical form would let decimalValue carry the written form and retire
writtenValue. A value none of the five kinds holds would add a kind. A business identifier found reissued for
another result within one organisation would demote tier (i). Lab sources sending ~ or exclusive reference bounds
would add them. Sources sending several typed ranges a page needs would add a ReferenceRange node. QUDT covering the
lab-sent forms, or SPHN's UCUM classes found under an open licence, would make an IRI cheap. A pair the matcher joins
that a person files Different over, or one it keeps apart that a person files Same over, would show a tier wrong.