Back to question 4 on the run's page · The doctor's card · With Cascade
The reasoning: With Cascade, question 4
With Cascade: the reasoning and the evidence behind each point
1. Your July 2025 chest CT found no blood clot in the lungs.
Facts it relied on · each checked against the record it cites
- ✓ The CT angiography of the chest report concluded there was no pulmonary embolism and the lungs were clear. CT angiography chest (pulmonary embolism protocol) · 2025-07-08 · S3 Cascade North Demo Hospital · Rde64c513, text of S3
- ✓ The pulmonary embolism condition entry is marked as ruled out. Pulmonary embolism · 2025-07-08 · S3 Cascade North Demo Hospital · C9f080aa6, status of S3
- ✓ The chest CT angiography procedure was done on 8 July 2025. CT angiography of the chest · 2025-07-08 · S3 Cascade North Demo Hospital · P7eb7ac1d, date
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
A CT pulmonary angiogram is the standard scan for diagnosing a pulmonary embolism; a negative scan rules it out. (ACR Appropriateness Criteria and ESC guidance on acute pulmonary embolism diagnosis.)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesYour July 2025 chest CT found no blood clot in the lungs.high confidence
The report's conclusion states there was no pulmonary embolism, and the related condition entry is marked as ruled out.
A fact it stated✓The CT angiography of the chest report concluded there was no pulmonary embolism and the lungs were clear.2025-07-08
says The CT angiography of the chest report concluded there was no pulmonary embolism and the lungs were clear. relies on the record for field text of S3 · words “No pulmonary embolism. Lungs are clear.” the pod holds CT angiography chest (pulmonary embolism protocol) · 2025-07-08 · S3 Cascade North Demo Hospital · Rde64c513, text of S3 the record says CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 Pod entry it citedCT angiography chest (pulmonary embolism protocol)Rde64c513
Rde64c513
label Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z reportCategory RAD reportCode 24627-2 reportConclusion No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. reportEffectiveTime 2025-07-08T22:30:00Z reportIssuedTime 2025-07-08T23:05:00Z reportName CT angiography chest (pulmonary embolism protocol) workflowStatus final Member recordstory-stopped-dr-11 revision at the source
record urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 its id at the source story-stopped-dr-1 source URL https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 revisions 2026-10-15 (version 1, in the download at /entry/8) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
A fact it stated✓The pulmonary embolism condition entry is marked as ruled out.2025-07-08
says The pulmonary embolism condition entry is marked as ruled out. relies on the record for field status of S3 the pod holds Pulmonary embolism · 2025-07-08 · S3 Cascade North Demo Hospital · C9f080aa6, status of S3 the record says Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 Pod entry it citedPulmonary embolismC9f080aa6
C9f080aa6
abatementDate 2025-07-08 clinicalStatus resolved conditionName Pulmonary embolism onsetDate 2025-07-08 snomedCode 59282003 verificationStatus refuted label Condition entry · Pulmonary embolism · 2025-07-08 Member recordstory-stopped-cond-21 revision at the source
record urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 its id at the source story-stopped-cond-2 source URL https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 revisions 2026-10-15 (version 1, in the download at /entry/2) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
A fact it stated✓The chest CT angiography procedure was done on 8 July 2025.2025-07-08
says The chest CT angiography procedure was done on 8 July 2025. relies on the record for field date the pod holds CT angiography of the chest · 2025-07-08 · S3 Cascade North Demo Hospital · P7eb7ac1d, date the record says CT angiography of the chest · status completed · on 2025-07-08 Pod entry it citedCT angiography of the chestP7eb7ac1d
P7eb7ac1d
label Procedure entry · CT angiography of the chest · 2025-07-08T22:30:00Z procedureDate 2025-07-08T22:30:00Z procedureName CT angiography of the chest workflowStatus completed Member recordstory-stopped-proc-11 revision at the source
record urn:uuid:3a4b65a8-320d-8e94-91a5-051719abd61d its id at the source story-stopped-proc-1 source URL https://cascade-north.demo.invalid/fhir/Procedure/story-stopped-proc-1 revisions 2026-10-15 (version 1, in the download at /entry/7) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeA CT pulmonary angiogram is the standard scan for diagnosing a pulmonary embolism; a negative scan rules it out.ACR Appropriateness Criteria and ESC guidance on acute pulmonary embolism diagnosis.
A CT pulmonary angiogram is the standard scan for diagnosing a pulmonary embolism; a negative scan rules it out.
Guideline the model named: ACR Appropriateness Criteria and ESC guidance on acute pulmonary embolism diagnosis.. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The report's conclusion states there was no pulmonary embolism, and the related condition entry is marked as ruled out.
| says | The CT angiography of the chest report concluded there was no pulmonary embolism and the lungs were clear. |
|---|---|
| relies on the record for | field text of S3 · words “No pulmonary embolism. Lungs are clear.” |
| the pod holds | CT angiography chest (pulmonary embolism protocol) · 2025-07-08 · S3 Cascade North Demo Hospital · Rde64c513, text of S3 |
| the record says | CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 |
Rde64c513
| label | Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z |
|---|---|
| reportCategory | RAD |
| reportCode | 24627-2 |
| reportConclusion | No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. |
| reportEffectiveTime | 2025-07-08T22:30:00Z |
| reportIssuedTime | 2025-07-08T23:05:00Z |
| reportName | CT angiography chest (pulmonary embolism protocol) |
| workflowStatus | final |
| record | urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 |
|---|---|
| its id at the source | story-stopped-dr-1 |
| source URL | https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/8) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
| says | The pulmonary embolism condition entry is marked as ruled out. |
|---|---|
| relies on the record for | field status of S3 |
| the pod holds | Pulmonary embolism · 2025-07-08 · S3 Cascade North Demo Hospital · C9f080aa6, status of S3 |
| the record says | Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 |
C9f080aa6
| abatementDate | 2025-07-08 |
|---|---|
| clinicalStatus | resolved |
| conditionName | Pulmonary embolism |
| onsetDate | 2025-07-08 |
| snomedCode | 59282003 |
| verificationStatus | refuted |
| label | Condition entry · Pulmonary embolism · 2025-07-08 |
| record | urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 |
|---|---|
| its id at the source | story-stopped-cond-2 |
| source URL | https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 |
| revisions | 2026-10-15 (version 1, in the download at /entry/2) |
| says | The chest CT angiography procedure was done on 8 July 2025. |
|---|---|
| relies on the record for | field date |
| the pod holds | CT angiography of the chest · 2025-07-08 · S3 Cascade North Demo Hospital · P7eb7ac1d, date |
| the record says | CT angiography of the chest · status completed · on 2025-07-08 |
P7eb7ac1d
| label | Procedure entry · CT angiography of the chest · 2025-07-08T22:30:00Z |
|---|---|
| procedureDate | 2025-07-08T22:30:00Z |
| procedureName | CT angiography of the chest |
| workflowStatus | completed |
| record | urn:uuid:3a4b65a8-320d-8e94-91a5-051719abd61d |
|---|---|
| its id at the source | story-stopped-proc-1 |
| source URL | https://cascade-north.demo.invalid/fhir/Procedure/story-stopped-proc-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/7) |
A CT pulmonary angiogram is the standard scan for diagnosing a pulmonary embolism; a negative scan rules it out.
Guideline the model named: ACR Appropriateness Criteria and ESC guidance on acute pulmonary embolism diagnosis.. This is the model's, not the records'; the report does not check it.
2. A blood test on the same day, the D-dimer, was raised, which is why the scan was done.
Facts it relied on · each checked against the record it cites
- ✓ The D-dimer result from 8 July 2025 was 0.92 mg/L FEU, flagged high against a reference of 0.49 or below. D-dimer · 0.92 mg/L{FEU} · 2025-07-08 · S3 Cascade North Demo Hospital · L41e35923, value
Absences it stated · what it searched for, and where
- none stated
Links it stated between its facts
- fact 1 bears on fact 2: The raised D-dimer on the same day is why the CT angiogram was ordered, and the CT ruled out the clot.
The model's own knowledge · not from the records
D-dimer has high sensitivity but low specificity, so a raised level is common with many conditions and is followed by imaging. (NICE NG158 and ESC pulmonary embolism guidance on D-dimer use.)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesA blood test on the same day, the D-dimer, was raised, which is why the scan was done.high confidence
A raised D-dimer prompts imaging to check for a clot, but it does not on its own mean a clot is present.
A fact it stated✓The D-dimer result from 8 July 2025 was 0.92 mg/L FEU, flagged high against a reference of 0.49 or below.2025-07-08 · 0.92 mg/L{FEU}
says The D-dimer result from 8 July 2025 was 0.92 mg/L FEU, flagged high against a reference of 0.49 or below. relies on the record for field value the pod holds D-dimer · 0.92 mg/L{FEU} · 2025-07-08 · S3 Cascade North Demo Hospital · L41e35923, value the record says D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 Pod entry it citedD-dimerL41e35923
L41e35923
referenceRange <=0.49 mg/L{FEU} referenceRangeHigh 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high resultClinicallyRelevantTime 2025-07-08T21:40:00Z resultInterpretationCode H resultUnit mg/L{FEU} resultValue 0.92 testCode 48065-7 testName D-dimer workflowStatus final label Lab result entry · D-dimer · 2025-07-08T21:40:00Z Member recordstory-stopped-ddimer-11 revision at the source
record urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 its id at the source story-stopped-ddimer-1 source URL https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 revisions 2026-10-15 (version 1, in the download at /entry/23) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeD-dimer has high sensitivity but low specificity, so a raised level is common with many conditions and is followed by imaging.NICE NG158 and ESC pulmonary embolism guidance on D-dimer use.
D-dimer has high sensitivity but low specificity, so a raised level is common with many conditions and is followed by imaging.
Guideline the model named: NICE NG158 and ESC pulmonary embolism guidance on D-dimer use.. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
A raised D-dimer prompts imaging to check for a clot, but it does not on its own mean a clot is present.
| says | The D-dimer result from 8 July 2025 was 0.92 mg/L FEU, flagged high against a reference of 0.49 or below. |
|---|---|
| relies on the record for | field value |
| the pod holds | D-dimer · 0.92 mg/L{FEU} · 2025-07-08 · S3 Cascade North Demo Hospital · L41e35923, value |
| the record says | D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 |
L41e35923
| referenceRange | <=0.49 mg/L{FEU} |
|---|---|
| referenceRangeHigh | 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high |
| resultClinicallyRelevantTime | 2025-07-08T21:40:00Z |
| resultInterpretationCode | H |
| resultUnit | mg/L{FEU} |
| resultValue | 0.92 |
| testCode | 48065-7 |
| testName | D-dimer |
| workflowStatus | final |
| label | Lab result entry · D-dimer · 2025-07-08T21:40:00Z |
| record | urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 |
|---|---|
| its id at the source | story-stopped-ddimer-1 |
| source URL | https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/23) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
D-dimer has high sensitivity but low specificity, so a raised level is common with many conditions and is followed by imaging.
Guideline the model named: NICE NG158 and ESC pulmonary embolism guidance on D-dimer use.. This is the model's, not the records'; the report does not check it.
3. Your records show no later clot in the lungs and no blood thinner medicine since then.
Facts it relied on · each checked against the record it cites
- ✓ The medication history lists atorvastatin and Jardiance as active, and metformin as completed in April 2024. None is a blood thinner. Atorvastatin 20 mg tablet · 2025-02-20 · S3 Cascade North Demo Hospital · Md8d1152a, name of S3
Absences it stated · what it searched for, and where
- ✗ A diagnosis of pulmonary embolism or other blood clot after the July 2025 scan searched: code snomed:59282003, pulmonary embolism, deep vein thrombosis, blood clot, after 2025-07-08 · All of her pod: condition history, medication history, lab results, procedures, reports and documents, and the person record, from the three sources S1 to S3, up to 2026-10-15. · checker: query found it
The model's own knowledge · not from the records
A pulmonary embolism is usually treated with a blood thinner, so the absence of one fits with no clot having been found. (ESC guidelines on acute pulmonary embolism, which set anticoagulation as the usual treatment.)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesYour records show no later clot in the lungs and no blood thinner medicine since then.medium confidence
The condition and medication lists hold no pulmonary embolism diagnosis and no anticoagulant after the scan.
A fact it stated✓The medication history lists atorvastatin and Jardiance as active, and metformin as completed in April 2024. None is a blood thinner.2025-02-20
says The medication history lists atorvastatin and Jardiance as active, and metformin as completed in April 2024. None is a blood thinner. relies on the record for field name of S3 the pod holds Atorvastatin 20 mg tablet · 2025-02-20 · S3 Cascade North Demo Hospital · Md8d1152a, name of S3 the record says Atorvastatin 20 mg tablet · status Active, prescribed · on 2025-02-20 Pod entry it citedAtorvastatin 20 mg tabletMd8d1152a
Md8d1152a
label Medication entry · Atorvastatin 20 mg tablet · 2025-02-20 dosage Take 1 tablet by mouth once daily. drugName Atorvastatin 20 mg tablet lifecycle MedicationActive prescribedOrReported prescribed prescriptionWrittenDate 2025-02-20 rxNormCode 617310 workflowStatus active Member recordstory-stopped-medrx-31 revision at the source
record urn:uuid:71d536c8-1f46-82af-83d4-60fd18ebe1c4 its id at the source story-stopped-medrx-3 source URL https://cascade-north.demo.invalid/fhir/MedicationRequest/story-stopped-medrx-3 revisions 2026-10-15 (version 1, in the download at /entry/6) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
An absence it stated✗Not found: A diagnosis of pulmonary embolism or other blood clot after the July 2025 scanlooked for pulmonary embolism, deep vein thrombosis, blood clot
what it says is missing A diagnosis of pulmonary embolism or other blood clot after the July 2025 scan a record of it would carry code snomed:59282003, pulmonary embolism, deep vein thrombosis, blood clot only a record on or after 2025-07-08 coverage, in its words All of her pod: condition history, medication history, lab results, procedures, reports and documents, and the person record, from the three sources S1 to S3, up to 2026-10-15. program check not backed: query found it The query that lookedask30 rows back · 2716 ms
tool ask input, as run {"pod":"tamsin-vale","format":"compact"} call number 1 what came back 30 rows in 2716 ms at 04:35:44 UTC
The model's own knowledgeA pulmonary embolism is usually treated with a blood thinner, so the absence of one fits with no clot having been found.ESC guidelines on acute pulmonary embolism, which set anticoagulation as the usual treatment.
A pulmonary embolism is usually treated with a blood thinner, so the absence of one fits with no clot having been found.
Guideline the model named: ESC guidelines on acute pulmonary embolism, which set anticoagulation as the usual treatment.. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The condition and medication lists hold no pulmonary embolism diagnosis and no anticoagulant after the scan.
| says | The medication history lists atorvastatin and Jardiance as active, and metformin as completed in April 2024. None is a blood thinner. |
|---|---|
| relies on the record for | field name of S3 |
| the pod holds | Atorvastatin 20 mg tablet · 2025-02-20 · S3 Cascade North Demo Hospital · Md8d1152a, name of S3 |
| the record says | Atorvastatin 20 mg tablet · status Active, prescribed · on 2025-02-20 |
Md8d1152a
| label | Medication entry · Atorvastatin 20 mg tablet · 2025-02-20 |
|---|---|
| dosage | Take 1 tablet by mouth once daily. |
| drugName | Atorvastatin 20 mg tablet |
| lifecycle | MedicationActive |
| prescribedOrReported | prescribed |
| prescriptionWrittenDate | 2025-02-20 |
| rxNormCode | 617310 |
| workflowStatus | active |
| record | urn:uuid:71d536c8-1f46-82af-83d4-60fd18ebe1c4 |
|---|---|
| its id at the source | story-stopped-medrx-3 |
| source URL | https://cascade-north.demo.invalid/fhir/MedicationRequest/story-stopped-medrx-3 |
| revisions | 2026-10-15 (version 1, in the download at /entry/6) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
| what it says is missing | A diagnosis of pulmonary embolism or other blood clot after the July 2025 scan |
|---|---|
| a record of it would carry | code snomed:59282003, pulmonary embolism, deep vein thrombosis, blood clot |
| only a record on or after | 2025-07-08 |
| coverage, in its words | All of her pod: condition history, medication history, lab results, procedures, reports and documents, and the person record, from the three sources S1 to S3, up to 2026-10-15. |
| program check | not backed: query found it |
| tool | ask |
|---|---|
| input, as run | {"pod":"tamsin-vale","format":"compact"} |
| call | number 1 |
| what came back | 30 rows in 2716 ms at 04:35:44 UTC |
A pulmonary embolism is usually treated with a blood thinner, so the absence of one fits with no clot having been found.
Guideline the model named: ESC guidelines on acute pulmonary embolism, which set anticoagulation as the usual treatment.. This is the model's, not the records'; the report does not check it.
npm run evals:report; never edited by hand. How the test works.