Back to question 4 on the run's page · The doctor's card · With Cascade
The reasoning: With Cascade, question 4
With Cascade: the reasoning and the evidence behind each point
1. Your summer 2025 chest CT found no blood clot in your lungs.
Facts it relied on · each checked against the record it cites
- ✓ CT angiography of the chest report: no pulmonary embolism, lungs clear. 2025-07-08 · Cascade North Demo Hospital
- ✓ Pulmonary embolism recorded as ruled out on the problem list. 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
A CT pulmonary angiogram is the standard test for confirming or excluding a lung clot, so a clear report on that test is a reliable negative for that date. (Use of CT pulmonary angiography to exclude pulmonary embolism when D-dimer is raised (NICE NG158 / ESC PE guidance).)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesYour summer 2025 chest CT found no blood clot in your lungs.high confidence
The CT was done specifically to look for a lung clot, and the report says there was none and the lungs were clear. Your problem list also marks the pulmonary embolism diagnosis as ruled out.
A fact it stated✓CT angiography of the chest report: no pulmonary embolism, lungs clear.2025-07-08 · final
says CT angiography of the chest report: no pulmonary embolism, lungs clear. relies on the record for name CT angiography chest (pulmonary embolism protocol) · code loinc:24627-2 · status final · when 2025-07-08 · words “No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine.” the record says CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 Pod entry it citedCT angiography chest (pulmonary embolism protocol)Rde64c513
Rde64c513
label Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z reportCategory RAD reportCode 24627-2 reportConclusion No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. reportEffectiveTime 2025-07-08T22:30:00Z reportIssuedTime 2025-07-08T23:05:00Z reportName CT angiography chest (pulmonary embolism protocol) workflowStatus final Member recordstory-stopped-dr-11 revision at the source
record urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 its id at the source story-stopped-dr-1 source URL https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 revisions 2026-10-15 (version 1, in the download at /entry/8) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
A fact it stated✓Pulmonary embolism recorded as ruled out on the problem list.2025-07-08 · refuted
says Pulmonary embolism recorded as ruled out on the problem list. relies on the record for name Pulmonary embolism · code snomed:59282003 · status refuted · start 2025-07-08 the record says Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 Pod entry it citedPulmonary embolismC9f080aa6
C9f080aa6
abatementDate 2025-07-08 clinicalStatus resolved conditionName Pulmonary embolism onsetDate 2025-07-08 snomedCode 59282003 verificationStatus refuted label Condition entry · Pulmonary embolism · 2025-07-08 Member recordstory-stopped-cond-21 revision at the source
record urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 its id at the source story-stopped-cond-2 source URL https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 revisions 2026-10-15 (version 1, in the download at /entry/2) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeA CT pulmonary angiogram is the standard test for confirming or excluding a lung clot, so a clear report on that test is a reliable negative for that date.Use of CT pulmonary angiography to exclude pulmonary embolism when D-dimer is raised (NICE NG158 / ESC PE guidance).
A CT pulmonary angiogram is the standard test for confirming or excluding a lung clot, so a clear report on that test is a reliable negative for that date.
Guideline the model named: Use of CT pulmonary angiography to exclude pulmonary embolism when D-dimer is raised (NICE NG158 / ESC PE guidance).. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The CT was done specifically to look for a lung clot, and the report says there was none and the lungs were clear. Your problem list also marks the pulmonary embolism diagnosis as ruled out.
| says | CT angiography of the chest report: no pulmonary embolism, lungs clear. |
|---|---|
| relies on the record for | name CT angiography chest (pulmonary embolism protocol) · code loinc:24627-2 · status final · when 2025-07-08 · words “No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine.” |
| the record says | CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 |
Rde64c513
| label | Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z |
|---|---|
| reportCategory | RAD |
| reportCode | 24627-2 |
| reportConclusion | No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. |
| reportEffectiveTime | 2025-07-08T22:30:00Z |
| reportIssuedTime | 2025-07-08T23:05:00Z |
| reportName | CT angiography chest (pulmonary embolism protocol) |
| workflowStatus | final |
| record | urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 |
|---|---|
| its id at the source | story-stopped-dr-1 |
| source URL | https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/8) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
| says | Pulmonary embolism recorded as ruled out on the problem list. |
|---|---|
| relies on the record for | name Pulmonary embolism · code snomed:59282003 · status refuted · start 2025-07-08 |
| the record says | Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 |
C9f080aa6
| abatementDate | 2025-07-08 |
|---|---|
| clinicalStatus | resolved |
| conditionName | Pulmonary embolism |
| onsetDate | 2025-07-08 |
| snomedCode | 59282003 |
| verificationStatus | refuted |
| label | Condition entry · Pulmonary embolism · 2025-07-08 |
| record | urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 |
|---|---|
| its id at the source | story-stopped-cond-2 |
| source URL | https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 |
| revisions | 2026-10-15 (version 1, in the download at /entry/2) |
A CT pulmonary angiogram is the standard test for confirming or excluding a lung clot, so a clear report on that test is a reliable negative for that date.
Guideline the model named: Use of CT pulmonary angiography to exclude pulmonary embolism when D-dimer is raised (NICE NG158 / ESC PE guidance).. This is the model's, not the records'; the report does not check it.
2. A blood test taken the same day was mildly raised, which was a screening result that the scan then answered.
Facts it relied on · each checked against the record it cites
- ✓ D-dimer result 0.92 mg/L FEU, flagged high (reference 0.49 or less). 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
A raised D-dimer is common with many conditions, so it needs imaging to decide whether a clot is present. (NICE NG158 (D-dimer followed by CTPA when raised in suspected PE).)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesA blood test taken the same day was mildly raised, which was a screening result that the scan then answered.medium confidence
D-dimer is a sensitive but non-specific test for clotting. A raised value prompts imaging, and it does not confirm a clot on its own.
A fact it stated✓D-dimer result 0.92 mg/L FEU, flagged high (reference 0.49 or less).2025-07-08 · 0.92 mg/L{FEU} · final
says D-dimer result 0.92 mg/L FEU, flagged high (reference 0.49 or less). relies on the record for name D-dimer · code loinc:48065-7 · value 0.92 mg/L{FEU} · status final · when 2025-07-08 the record says D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 Pod entry it citedD-dimerL41e35923
L41e35923
referenceRange <=0.49 mg/L{FEU} referenceRangeHigh 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high resultClinicallyRelevantTime 2025-07-08T21:40:00Z resultInterpretationCode H resultUnit mg/L{FEU} resultValue 0.92 testCode 48065-7 testName D-dimer workflowStatus final label Lab result entry · D-dimer · 2025-07-08T21:40:00Z Member recordstory-stopped-ddimer-11 revision at the source
record urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 its id at the source story-stopped-ddimer-1 source URL https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 revisions 2026-10-15 (version 1, in the download at /entry/23) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeA raised D-dimer is common with many conditions, so it needs imaging to decide whether a clot is present.NICE NG158 (D-dimer followed by CTPA when raised in suspected PE).
A raised D-dimer is common with many conditions, so it needs imaging to decide whether a clot is present.
Guideline the model named: NICE NG158 (D-dimer followed by CTPA when raised in suspected PE).. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
D-dimer is a sensitive but non-specific test for clotting. A raised value prompts imaging, and it does not confirm a clot on its own.
| says | D-dimer result 0.92 mg/L FEU, flagged high (reference 0.49 or less). |
|---|---|
| relies on the record for | name D-dimer · code loinc:48065-7 · value 0.92 mg/L{FEU} · status final · when 2025-07-08 |
| the record says | D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 |
L41e35923
| referenceRange | <=0.49 mg/L{FEU} |
|---|---|
| referenceRangeHigh | 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high |
| resultClinicallyRelevantTime | 2025-07-08T21:40:00Z |
| resultInterpretationCode | H |
| resultUnit | mg/L{FEU} |
| resultValue | 0.92 |
| testCode | 48065-7 |
| testName | D-dimer |
| workflowStatus | final |
| label | Lab result entry · D-dimer · 2025-07-08T21:40:00Z |
| record | urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 |
|---|---|
| its id at the source | story-stopped-ddimer-1 |
| source URL | https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/23) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
A raised D-dimer is common with many conditions, so it needs imaging to decide whether a clot is present.
Guideline the model named: NICE NG158 (D-dimer followed by CTPA when raised in suspected PE).. This is the model's, not the records'; the report does not check it.
3. The chest pain you had then was recorded as chest wall pain, and it resolved by 22 July 2025.
Facts it relied on · each checked against the record it cites
- ✓ Chest wall pain, onset 8 July 2025, resolved and abated 22 July 2025. 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
Chest wall pain is a common, usually musculoskeletal cause of chest pain once a serious cause such as a clot has been excluded. (NICE CKS chest pain guidance (non-cardiac chest pain assessment).)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesThe chest pain you had then was recorded as chest wall pain, and it resolved by 22 July 2025.medium confidence
The problem list gives chest wall pain as the working diagnosis from 8 July 2025, marked resolved and abated on 22 July 2025, after the scan had ruled out a clot.
A fact it stated✓Chest wall pain, onset 8 July 2025, resolved and abated 22 July 2025.2025-07-08 · resolved
says Chest wall pain, onset 8 July 2025, resolved and abated 22 July 2025. relies on the record for name Chest wall pain · code snomed:102588006 · status resolved · start 2025-07-08 the record says Chest wall pain · status resolved, confirmed · on 2025-07-08 · ended 2025-07-22 Pod entry it citedChest wall painCc4ea67d7
Cc4ea67d7
abatementDate 2025-07-22 clinicalStatus resolved conditionName Chest wall pain onsetDate 2025-07-08 snomedCode 102588006 verificationStatus confirmed label Condition entry · Chest wall pain · 2025-07-08 Member recordstory-stopped-cond-31 revision at the source
record urn:uuid:321216ac-2814-8b40-8b55-76c97c9269bc its id at the source story-stopped-cond-3 source URL https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-3 revisions 2026-10-15 (version 1, in the download at /entry/3) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeChest wall pain is a common, usually musculoskeletal cause of chest pain once a serious cause such as a clot has been excluded.NICE CKS chest pain guidance (non-cardiac chest pain assessment).
Chest wall pain is a common, usually musculoskeletal cause of chest pain once a serious cause such as a clot has been excluded.
Guideline the model named: NICE CKS chest pain guidance (non-cardiac chest pain assessment).. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The problem list gives chest wall pain as the working diagnosis from 8 July 2025, marked resolved and abated on 22 July 2025, after the scan had ruled out a clot.
| says | Chest wall pain, onset 8 July 2025, resolved and abated 22 July 2025. |
|---|---|
| relies on the record for | name Chest wall pain · code snomed:102588006 · status resolved · start 2025-07-08 |
| the record says | Chest wall pain · status resolved, confirmed · on 2025-07-08 · ended 2025-07-22 |
Cc4ea67d7
| abatementDate | 2025-07-22 |
|---|---|
| clinicalStatus | resolved |
| conditionName | Chest wall pain |
| onsetDate | 2025-07-08 |
| snomedCode | 102588006 |
| verificationStatus | confirmed |
| label | Condition entry · Chest wall pain · 2025-07-08 |
| record | urn:uuid:321216ac-2814-8b40-8b55-76c97c9269bc |
|---|---|
| its id at the source | story-stopped-cond-3 |
| source URL | https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-3 |
| revisions | 2026-10-15 (version 1, in the download at /entry/3) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
Chest wall pain is a common, usually musculoskeletal cause of chest pain once a serious cause such as a clot has been excluded.
Guideline the model named: NICE CKS chest pain guidance (non-cardiac chest pain assessment).. This is the model's, not the records'; the report does not check it.
4. The records show no lung or leg clot after that scan, but they stop at mid-October 2026.
Facts it relied on · each checked against the record it cites
- none: this point rests on the agent's own knowledge
Absences it stated · what it searched for, and where
- ✓ A later lung clot or leg clot (DVT) recorded after the July 2025 scan. searched: code snomed:59282003, pulmonary embolism, deep vein thrombosis, DVT, after 2025-07-09 · Her pod's condition history, procedures, lab results and reports and documents, from the Cascade North Demo Hospital records retrieved 2026-10-15.
The model's own knowledge · not from the records
Records from a single provider can miss clots diagnosed elsewhere, so an absence here does not rule out a later clot. (No specific guideline; general principle that a single provider's records can be incomplete.)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesThe records show no lung or leg clot after that scan, but they stop at mid-October 2026.medium confidence
The problem list and the reports and procedures in the pod contain no later pulmonary embolism or deep vein thrombosis entry, so the absence is limited to the period covered by the records.
An absence it stated✓Not found: A later lung clot or leg clot (DVT) recorded after the July 2025 scan.looked for pulmonary embolism, deep vein thrombosis, DVT
what it says is missing A later lung clot or leg clot (DVT) recorded after the July 2025 scan. a record of it would carry code snomed:59282003, pulmonary embolism, deep vein thrombosis, DVT only a record on or after 2025-07-09 coverage, in its words Her pod's condition history, procedures, lab results and reports and documents, from the Cascade North Demo Hospital records retrieved 2026-10-15. program check backed: the query ran and returned nothing matching The query that lookedask30 rows back · 1813 ms
tool ask input, as run {"pod":"tamsin-vale","format":"compact"} call number 1 what came back 30 rows in 1813 ms at 02:33:19 UTC
The model's own knowledgeRecords from a single provider can miss clots diagnosed elsewhere, so an absence here does not rule out a later clot.No specific guideline; general principle that a single provider's records can be incomplete.
Records from a single provider can miss clots diagnosed elsewhere, so an absence here does not rule out a later clot.
Guideline the model named: No specific guideline; general principle that a single provider's records can be incomplete.. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The problem list and the reports and procedures in the pod contain no later pulmonary embolism or deep vein thrombosis entry, so the absence is limited to the period covered by the records.
| what it says is missing | A later lung clot or leg clot (DVT) recorded after the July 2025 scan. |
|---|---|
| a record of it would carry | code snomed:59282003, pulmonary embolism, deep vein thrombosis, DVT |
| only a record on or after | 2025-07-09 |
| coverage, in its words | Her pod's condition history, procedures, lab results and reports and documents, from the Cascade North Demo Hospital records retrieved 2026-10-15. |
| program check | backed: the query ran and returned nothing matching |
| tool | ask |
|---|---|
| input, as run | {"pod":"tamsin-vale","format":"compact"} |
| call | number 1 |
| what came back | 30 rows in 1813 ms at 02:33:19 UTC |
Records from a single provider can miss clots diagnosed elsewhere, so an absence here does not rule out a later clot.
Guideline the model named: No specific guideline; general principle that a single provider's records can be incomplete.. This is the model's, not the records'; the report does not check it.
Links across its points, in the agent's words
- item 2 fact 1 bears on item 1 fact 1: The D-dimer was drawn the same day as the CT; the CT is the test that excluded the clot the D-dimer was screening for.
- item 3 fact 1 bears on item 1 fact 2: The chest wall pain diagnosis dates from the same day as the scan that ruled out pulmonary embolism.
npm run evals:report; never edited by hand. How the test works.