Back to question 4 on the run's page · The doctor's card · With Cascade
The reasoning: With Cascade, question 4
With Cascade: the reasoning and the evidence behind each point
1. The CT scan of your chest in July 2025 showed no blood clot in the lung.
Facts it relied on · each checked against the record it cites
- ✓ CT angiography of the chest (pulmonary embolism protocol) reported no pulmonary embolism, clear lungs 2025-07-08 · Cascade North Demo Hospital
- ✓ CT angiography of the chest was performed 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
CT pulmonary angiography is the standard imaging test to confirm or exclude a pulmonary embolism; a clear study essentially excludes a clot in the main lung arteries. (ACR Appropriateness Criteria / ESC acute pulmonary embolism guidelines)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesThe CT scan of your chest in July 2025 showed no blood clot in the lung.high confidence
The final report's conclusion states no pulmonary embolism, and the scan was done as a pulmonary embolism protocol study.
A fact it stated✓CT angiography of the chest (pulmonary embolism protocol) reported no pulmonary embolism, clear lungs2025-07-08 · final
says CT angiography of the chest (pulmonary embolism protocol) reported no pulmonary embolism, clear lungs relies on the record for name CT angiography chest (pulmonary embolism protocol) · status final · when 2025-07-08 · words “No pulmonary embolism. Lungs are clear.” the record says CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 Pod entry it citedCT angiography chest (pulmonary embolism protocol)Rde64c513
Rde64c513
label Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z reportCategory RAD reportCode 24627-2 reportConclusion No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. reportEffectiveTime 2025-07-08T22:30:00Z reportIssuedTime 2025-07-08T23:05:00Z reportName CT angiography chest (pulmonary embolism protocol) workflowStatus final Member recordstory-stopped-dr-11 revision at the source
record urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 its id at the source story-stopped-dr-1 source URL https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 revisions 2026-10-15 (version 1, in the download at /entry/8) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
A fact it stated✓CT angiography of the chest was performed2025-07-08 · completed
says CT angiography of the chest was performed relies on the record for name CT angiography of the chest · status completed · when 2025-07-08 the record says CT angiography of the chest · status completed · on 2025-07-08 Pod entry it citedCT angiography of the chestP7eb7ac1d
P7eb7ac1d
label Procedure entry · CT angiography of the chest · 2025-07-08T22:30:00Z procedureDate 2025-07-08T22:30:00Z procedureName CT angiography of the chest workflowStatus completed Member recordstory-stopped-proc-11 revision at the source
record urn:uuid:3a4b65a8-320d-8e94-91a5-051719abd61d its id at the source story-stopped-proc-1 source URL https://cascade-north.demo.invalid/fhir/Procedure/story-stopped-proc-1 revisions 2026-10-15 (version 1, in the download at /entry/7) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeCT pulmonary angiography is the standard imaging test to confirm or exclude a pulmonary embolism; a clear study essentially excludes a clot in the main lung arteries.ACR Appropriateness Criteria / ESC acute pulmonary embolism guidelines
CT pulmonary angiography is the standard imaging test to confirm or exclude a pulmonary embolism; a clear study essentially excludes a clot in the main lung arteries.
Guideline the model named: ACR Appropriateness Criteria / ESC acute pulmonary embolism guidelines. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The final report's conclusion states no pulmonary embolism, and the scan was done as a pulmonary embolism protocol study.
| says | CT angiography of the chest (pulmonary embolism protocol) reported no pulmonary embolism, clear lungs |
|---|---|
| relies on the record for | name CT angiography chest (pulmonary embolism protocol) · status final · when 2025-07-08 · words “No pulmonary embolism. Lungs are clear.” |
| the record says | CT angiography chest (pulmonary embolism protocol) · status final · on 2025-07-08 |
Rde64c513
| label | Report entry · CT angiography chest (pulmonary embolism protocol) · 2025-07-08T22:30:00Z |
|---|---|
| reportCategory | RAD |
| reportCode | 24627-2 |
| reportConclusion | No pulmonary embolism. Lungs are clear. No pleural or pericardial effusion. Mild degenerative changes of the thoracic spine. |
| reportEffectiveTime | 2025-07-08T22:30:00Z |
| reportIssuedTime | 2025-07-08T23:05:00Z |
| reportName | CT angiography chest (pulmonary embolism protocol) |
| workflowStatus | final |
| record | urn:uuid:1889f959-6178-8833-9850-96a22a25cc04 |
|---|---|
| its id at the source | story-stopped-dr-1 |
| source URL | https://cascade-north.demo.invalid/fhir/DiagnosticReport/story-stopped-dr-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/8) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
| says | CT angiography of the chest was performed |
|---|---|
| relies on the record for | name CT angiography of the chest · status completed · when 2025-07-08 |
| the record says | CT angiography of the chest · status completed · on 2025-07-08 |
P7eb7ac1d
| label | Procedure entry · CT angiography of the chest · 2025-07-08T22:30:00Z |
|---|---|
| procedureDate | 2025-07-08T22:30:00Z |
| procedureName | CT angiography of the chest |
| workflowStatus | completed |
| record | urn:uuid:3a4b65a8-320d-8e94-91a5-051719abd61d |
|---|---|
| its id at the source | story-stopped-proc-1 |
| source URL | https://cascade-north.demo.invalid/fhir/Procedure/story-stopped-proc-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/7) |
CT pulmonary angiography is the standard imaging test to confirm or exclude a pulmonary embolism; a clear study essentially excludes a clot in the main lung arteries.
Guideline the model named: ACR Appropriateness Criteria / ESC acute pulmonary embolism guidelines. This is the model's, not the records'; the report does not check it.
2. Pulmonary embolism is recorded as ruled out in your condition list.
Facts it relied on · each checked against the record it cites
- ✓ Pulmonary embolism recorded as ruled out / refuted 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesPulmonary embolism is recorded as ruled out in your condition list.high confidence
The diagnosis entry carries a refuted status, matching the scan result.
A fact it stated✓Pulmonary embolism recorded as ruled out / refuted2025-07-08 · refuted
says Pulmonary embolism recorded as ruled out / refuted relies on the record for name Pulmonary embolism · status refuted · start 2025-07-08 the record says Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 Pod entry it citedPulmonary embolismC9f080aa6
C9f080aa6
abatementDate 2025-07-08 clinicalStatus resolved conditionName Pulmonary embolism onsetDate 2025-07-08 snomedCode 59282003 verificationStatus refuted label Condition entry · Pulmonary embolism · 2025-07-08 Member recordstory-stopped-cond-21 revision at the source
record urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 its id at the source story-stopped-cond-2 source URL https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 revisions 2026-10-15 (version 1, in the download at /entry/2) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
The diagnosis entry carries a refuted status, matching the scan result.
| says | Pulmonary embolism recorded as ruled out / refuted |
|---|---|
| relies on the record for | name Pulmonary embolism · status refuted · start 2025-07-08 |
| the record says | Pulmonary embolism · status resolved, refuted · on 2025-07-08 · ended 2025-07-08 |
C9f080aa6
| abatementDate | 2025-07-08 |
|---|---|
| clinicalStatus | resolved |
| conditionName | Pulmonary embolism |
| onsetDate | 2025-07-08 |
| snomedCode | 59282003 |
| verificationStatus | refuted |
| label | Condition entry · Pulmonary embolism · 2025-07-08 |
| record | urn:uuid:da3dce7b-7ade-8427-acd9-3d6ea9099248 |
|---|---|
| its id at the source | story-stopped-cond-2 |
| source URL | https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-2 |
| revisions | 2026-10-15 (version 1, in the download at /entry/2) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
3. The raised D-dimer was why the scan was done; it was not itself proof of a clot.
Facts it relied on · each checked against the record it cites
- ✓ D-dimer was high at 0.92 (normal up to 0.49) 2025-07-08 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
The model's own knowledge · not from the records
D-dimer has high sensitivity but low specificity for venous clots, so positives are followed by imaging. (ESC 2019 acute pulmonary embolism guidelines)
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesThe raised D-dimer was why the scan was done; it was not itself proof of a clot.medium confidence
D-dimer rises with many conditions, so a raised value needs imaging to settle the question.
A fact it stated✓D-dimer was high at 0.92 (normal up to 0.49)2025-07-08 · 0.92 mg/L{FEU}
says D-dimer was high at 0.92 (normal up to 0.49) relies on the record for name D-dimer · value 0.92 mg/L{FEU} · when 2025-07-08 the record says D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 Pod entry it citedD-dimerL41e35923
L41e35923
referenceRange <=0.49 mg/L{FEU} referenceRangeHigh 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high resultClinicallyRelevantTime 2025-07-08T21:40:00Z resultInterpretationCode H resultUnit mg/L{FEU} resultValue 0.92 testCode 48065-7 testName D-dimer workflowStatus final label Lab result entry · D-dimer · 2025-07-08T21:40:00Z Member recordstory-stopped-ddimer-11 revision at the source
record urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 its id at the source story-stopped-ddimer-1 source URL https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 revisions 2026-10-15 (version 1, in the download at /entry/23) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
The model's own knowledgeD-dimer has high sensitivity but low specificity for venous clots, so positives are followed by imaging.ESC 2019 acute pulmonary embolism guidelines
D-dimer has high sensitivity but low specificity for venous clots, so positives are followed by imaging.
Guideline the model named: ESC 2019 acute pulmonary embolism guidelines. This is the model's, not the records'; the report does not check it.
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
D-dimer rises with many conditions, so a raised value needs imaging to settle the question.
| says | D-dimer was high at 0.92 (normal up to 0.49) |
|---|---|
| relies on the record for | name D-dimer · value 0.92 mg/L{FEU} · when 2025-07-08 |
| the record says | D-dimer · value 0.92 mg/L{FEU} · status final · on 2025-07-08 |
L41e35923
| referenceRange | <=0.49 mg/L{FEU} |
|---|---|
| referenceRangeHigh | 41e3592370849fec9b70b52fc5896d32b0c21872db58f937a6fc7d4244119502-reference-high |
| resultClinicallyRelevantTime | 2025-07-08T21:40:00Z |
| resultInterpretationCode | H |
| resultUnit | mg/L{FEU} |
| resultValue | 0.92 |
| testCode | 48065-7 |
| testName | D-dimer |
| workflowStatus | final |
| label | Lab result entry · D-dimer · 2025-07-08T21:40:00Z |
| record | urn:uuid:e188f12f-5126-86d5-9c0c-cec283c12712 |
|---|---|
| its id at the source | story-stopped-ddimer-1 |
| source URL | https://cascade-north.demo.invalid/fhir/Observation/story-stopped-ddimer-1 |
| revisions | 2026-10-15 (version 1, in the download at /entry/23) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
D-dimer has high sensitivity but low specificity for venous clots, so positives are followed by imaging.
Guideline the model named: ESC 2019 acute pulmonary embolism guidelines. This is the model's, not the records'; the report does not check it.
4. The chest symptoms at that time were recorded as chest wall pain, which resolved.
Facts it relied on · each checked against the record it cites
- ✓ Chest wall pain, resolved 2025-07-22 · Cascade North Demo Hospital
Absences it stated · what it searched for, and where
- none stated
What the judges said of this chain
- haiku-5-5: complete, faithful
The evidence, as a graph · built only from what this agent cited, plus lookups
What it raisesThe chest symptoms at that time were recorded as chest wall pain, which resolved.medium confidence
A chest wall pain problem started the same day and is marked resolved on 22 July 2025.
A fact it stated✓Chest wall pain, resolved2025-07-22 · resolved
says Chest wall pain, resolved relies on the record for name Chest wall pain · status resolved · end 2025-07-22 the record says Chest wall pain · status resolved, confirmed · on 2025-07-08 · ended 2025-07-22 Pod entry it citedChest wall painCc4ea67d7
Cc4ea67d7
abatementDate 2025-07-22 clinicalStatus resolved conditionName Chest wall pain onsetDate 2025-07-08 snomedCode 102588006 verificationStatus confirmed label Condition entry · Chest wall pain · 2025-07-08 Member recordstory-stopped-cond-31 revision at the source
record urn:uuid:321216ac-2814-8b40-8b55-76c97c9269bc its id at the source story-stopped-cond-3 source URL https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-3 revisions 2026-10-15 (version 1, in the download at /entry/3) Source documentCascade North Demo Hospitalarrived 2026-10-15
author Cascade North Demo Hospital retrieved (arrival) 2026-10-15T00:00:00Z answered as of 2026-10-15T00:00:00Z server https://cascade-north.demo.invalid/fhir document ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc
Left to right: what the answer raises, then the facts, absences and knowledge the agent itself wrote, then the pod entry it cited, the member records the pod merged into that entry, and the source documents with their authors and arrival dates. Only the first two columns are the agent's; the rest is the pod's own provenance, looked up, not reasoned. Dashed: the model's own knowledge, not from the records.
A chest wall pain problem started the same day and is marked resolved on 22 July 2025.
| says | Chest wall pain, resolved |
|---|---|
| relies on the record for | name Chest wall pain · status resolved · end 2025-07-22 |
| the record says | Chest wall pain · status resolved, confirmed · on 2025-07-08 · ended 2025-07-22 |
Cc4ea67d7
| abatementDate | 2025-07-22 |
|---|---|
| clinicalStatus | resolved |
| conditionName | Chest wall pain |
| onsetDate | 2025-07-08 |
| snomedCode | 102588006 |
| verificationStatus | confirmed |
| label | Condition entry · Chest wall pain · 2025-07-08 |
| record | urn:uuid:321216ac-2814-8b40-8b55-76c97c9269bc |
|---|---|
| its id at the source | story-stopped-cond-3 |
| source URL | https://cascade-north.demo.invalid/fhir/Condition/story-stopped-cond-3 |
| revisions | 2026-10-15 (version 1, in the download at /entry/3) |
| author | Cascade North Demo Hospital |
|---|---|
| retrieved (arrival) | 2026-10-15T00:00:00Z |
| answered as of | 2026-10-15T00:00:00Z |
| server | https://cascade-north.demo.invalid/fhir |
| document | ni:///sha-256;UhKvP6jJxoy_fEiJXl9dnzVlPrLvzuzV2mE65cYwAJc |
Links across its points, in the agent's words
- item 3 fact 1 bears on item 1 fact 1: The raised D-dimer led to the CT scan, which found no clot.
npm run evals:report; never edited by hand. How the test works.